Commands Top903H; Outputs And Accessories - entrematic Ditec TOP603H Manuale Tecnico

Ocultar thumbs Ver también para Ditec TOP603H:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 196
19.2

Commands TOP903H

Command
14
15
NO
STEP-BY-STEP
OPENING
NO
STEP-BY-STEP
A
OPENING
ADDITIONAL
FUNCTIONS
NO
STEP-BY-STEP
b
OPENING
ADDITIONAL
FUNCTIONS
NC
STOP
NC
REVERSAL
SAFETY
19.3
Outputs and accessories TOP903H
Output
Value - Accessories
24 V
24 V
230 V~ / 25W
max 1.6A
8
9
max 230V~ / 60W
1
2
GOL148REA
16
17
WARNING: make a jumper for all unused NC contacts.
i
Keep the YELLOW and/or GREEN connectors if accessories are to be connected.
Function
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
See parameter C6.
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
See parameter C6.
The opening of the safety contact causes the current movement
to stop, and the automatic closure is disabled (if C5=000).
The opening of the safety contact triggers a reversal of the
movement (reopening) during the closing operation, and the
flashing of the courtesy light.
After the 3rd consecutive reversed movement, the automatic
closure is disabled (if active) and the courtesy light flashes
for about 10 min.
Power supply to accessories.
/ 0.3A for 2s
The maximum continuous absorption refers to all the accessories
/ 0.08A con-
installed. Yellow wire (+24V) and black wire (-0V) with TOP905CAB2.
tinuous
Flashing light (with TOP905AC).
LAMP
Activated during opening and closing operations.
Electric lock.
Activated for 1s at each start (even with the door open).
Courtesy light.
Activated for 120s at the end of every operation.
An additional E14 courtesy light can be connected (in parallel) - max
60W or equivalent.
DO NOT CONNECT fluorescent tubular lamps.
NB: some energy-saving lamps may interfere with the radio signal.
Antenna
Connect the supplied antenna wire (345mm), or alternatively the
GOL148REA antenna, using an RG58 coaxial cable.
Description
Description
84

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ditec top903h

Tabla de contenido