3. Technical specifications
Power
Power
Thrust
Opening speed
Closing speed
Maximum door area (*)
Maximum door weight
Service class
Intermittence
Ambient temperature
Degree of protection
Acoustic pressure emitted at a
distance of 2m
Control panel
Control panel fuse
Motor power supply
Power supply for accessories
Radio frequency
Maximum remote control range
Remote control functions /
programmable keys
Courtesy light
(*) N.B.: the maximum door area has been calculated using a specific door weight of 12 kg/ m² (most common).
For values <12 kg/m² the maximum area in m² is larger. For values >12 kg/m² the maximum area in m² is
smaller (see graphs in par. 3.2 and 3.3)
Max. carriage stroke
Maximum height of door

3.1 Operating instructions

Service class: 3 (minimum 10-5 years of working life with 30-60 cycles per day).
Applications: FREQUENT (for multi-family type entrances or small apartment blocks with frequent
vehicle access).
-
The performance characteristics refer to the recommended weight (approx. 2/3 of the maximum
permitted weight). When used with the maximum permitted weight, a reduction in the above
mentioned performance levels can be expected.
-
The service class, running times and number of consecutive cycles are merely indicative, having
been statistically determined under average operating conditions and therefore not necessarily
applicable to specific conditions of use.
-
Each automatic entrance has variable elements such as friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics or working life of
the entrance itself or its components (including the automatic devices). The installer should
apply suitable safety conditions for each particular installation.
Ditec TOP603H
230V~, 50/60 Hz
140W
600 N
210mm/s
140mm/s
9.5 m²
116kg
3 - FREQUENT
S2 = 5 min
S3 = 25%
-20°C
+50°C
IP20
≤69 dB (A)
TP603EL
1.6A T (delayed)
24V= / 9.5A
24V= / 0.3A max 2 s
24V= / 0.08A continuous
433.92 MHz
15-50m
50
E14 max 60W
TOP803T3 guide
2890 +/- 25mm
2450mm
58
Ditec TOP903H
230V~, 50/60 Hz
170W
1000 N
210mm/s
140mm/s
17.3 m²
210kg
3 - FREQUENT
S2 = 5 min
S3 = 25%
-20°C
+50°C
IP20
≤69 dB (A)
TP903EL
2x1.6A T (delayed)
24V= / 10.5A
24V= / 0.3A max 2 s
24V= / 0.08A continuous
433.92 MHz
15-50m
50
E14 max 60W
TOP803T4 guide
3978 +/-25mm
3500mm

Publicidad