Auxiliary card
000 = without TOP905AC
001 = with TOP905AC
Relay 1 (with auxiliary card TOP905AC) if A9 = 1
000 = no function
001 = electric lock (activated for 1 s at each start)
002 = flashing light (activated when the motor is moving)
003 = photocell test (transmitter voltage interrupted)
004 = door OPEN (activated with door fully open)
005 = door CLOSED (activated with door fully closed)
006 = green light (activated with door fully open)
007 = red light (deactivated with door fully open)
Relay 2 (with auxiliary card TOP905AC) if A9 = 1
000 = no function
001 = electric lock (activated for 1 s at each start)
002 = flashing light (activated when the motor is moving)
003 = photocell test (transmitter voltage interrupted)
004 = door OPEN (activated with door fully open)
500 = door CLOSED (activated with door fully closed)
006 = green light (activated with door fully open)
007 = red light (deactivated with door fully open)
Closing edge protection (with auxiliary card TOP905AC)
000 = disabled
001 = optic edge FUTURE USE
002 = edge 8k2
Detection of stroke with little weight / friction
000 = door with little weight / low friction
001= door with standard weight / normal friction
Selection of automatic closure
000 = disabled
001 = 5 sec - 010 = 50 sec
011 = 1 min - 040 = 30 min
With automatic closure enabled, the OPEN/STOP/CLOSE/
STOP command becomes a simple OPENING command.
The enabling of automatic closure is visualised on the display
with
(3 points) flashing with the door open, or fixed
after a step-by-step STOP command.
The step-by-step STOP commands given when automatic clo-
sure is enabled are not permanent.
DO NOT USE
Maintenance alarm
000 = disabled
001..009 (1,000 door operations)
Example: 005 = 5,000 door operations
When the maintenance interval has expired, the courtesy light
flashes after every movement.
A new maintenance alarm setting will reset the counter.
Function, setting range, unit
90
Factory
Value
settings
000 - 001
000 - 007
000 - 007
000 - 001
000 - 001
000 - 008
000 - 009