Electrical Connections Top903H - entrematic Ditec TOP603H Manuale Tecnico

Ocultar thumbs Ver también para Ditec TOP603H:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 196

19. Electrical connections TOP903H

Installation, electrical connections and adjustments must be performed by qualified person-
nel, in accordance with Good Working Methods and in compliance with the current regulations.
The automation must be installed in compliance with Standards EN 12453, EN 12445 and EN
12635.
The safety devices must be working properly.
Garages without a second entrance must be equipped with an external emergency release device
(to be ordered separately).
If there is a pedestrian door incorporated into the garage door, it must be closed and equipped
with a safety device that prevents it being activated when the garage door is open.
device must be connected to the EMERGENCY STOP input.
In the external automation section, the connections to the mains power supply and any
other low voltage wires (230V) must be made on an independent channel separated from
the connections to the command and safety devices (SELV = Safety Extra Low Voltage).
F1.6AT line
1 2 3
4 5
N
Power supply
Y E L L
O W
G R E
E N
F1.6AT electriclock
24V 0V 24V
6
7
10
8 9
Electriclock
Power unit
L PE
11 12
24V
Motor
81
This safety
SIG
Antenna
GND
Step by step
DO NOT USE

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ditec top903h

Tabla de contenido