20. Commands and indications

8
5
A
B
Status messages
A
door fully OPEN
B
door between the two end stop positions
door fully CLOSED
C
While the door is OPENING, the display visualises:
A
C
B
While the door is CLOSING, the display visualises:
A
B
C

20.1 Deleting the memorised stroke values

If you press the
[6] and [7] keys simultaneously for a few seconds, the display flashes
, the stroke values are deleted, and the display visualises L4.
NB: the remote controls are not deleted.

20.2 Restoring the factory settings

Remove the plug from the
12s.
The display flashes
All the adjustments previously made are deleted, and the factory values are restored.
The stroke values are deleted.
Reconnect the plug to the
The display visualises L4.
NB: the remote controls are not deleted.
res.
6
7
C
.
.
connector, then press the
, first slowly and then more quickly.
connector.
85
5
Button for door closure / decreased value
6
Menu button / confirm (stroke
memorisation)
7
Button for door opening / increased value
8
Display
The procedures and adjustments can only
be carried out when the display is in mode
A, B or C.