Menu
Number of the control panel version:
The digits from 000 to 007 are visualised in sequence.
Example: version 04 of 20.05.10
04200510
01234567
Help mode
000= control panel free, menu items adjustable
001= control panel locked, menu items not adjustable
002= data output (auxiliary card) - FUTURE USE
This setting is only possible if the EMERGENCY STOP con-
nector (1, green) and the photocell connector (2, yellow) are
disconnected.
Operation count (not adjustable).
The digits from 0 to 5 are visualised in sequence.
Example: 8,000 operations
008000
012345
DO NOT USE
Adjustment of automatic closing time after partial opening.
000 = disabled
001 = 5 secs... 010 = 50 secs
011 = 1 min ... 040 = 30 min
Selection of partial opening distance.
000 = 5 cm
100 = 500 cm
Adjustment of the courtesy light switch-on time.
000 = 0 sec
001 = 10 sec
060 = 600 sec
Adjustment of the automatic closing time after photocell in-
tervention.
000 = disabled
001 = 0.5 s ... 019 = 9.5 s
The count begins with the door fully open, and the closing
operation is performed even with automatic closure (b4 / C1)
disabled.
WARNING: automatic closure is not disabled on the third con-
secutive direction reversal.
Selection of automatic closure after a STOP
000 = disabled
001 = enabled
Function, setting range, unit
91
Factory
Value
settings
000 - 002
000 - 040
000 - 100
000 - 060
000 - 019
000 - 001