14. Commands and indications

8
5
A
B

Status messages

A
door fully OPEN
door between the two end stop positions
B
C
door fully CLOSED
While the door is OPENING, the display visualises:
A
C
B
While the door is CLOSING, the display visualises:
A
B
C

14.1 Deleting the memorised stroke values

If you press the
[6] and [7] keys simultaneously for a few seconds, the display flashes
stroke values are deleted, and the display visualises L ... 4.
NB: the remote controls are not deleted.

14.2 Restoring the factory settings

Remove the plug from the
12s.
The display flashes
, first slowly and then more quickly.
All the adjustments previously made are deleted, and the factory values are restored.
The stroke values are deleted.
Reconnect the plug to the
The display visualises L ... 4.
NB: the remote controls are not deleted.
res.
6
7
C
.
.
connector, then press the
connector.
75
5
Button for door closure / decreased value
6
Menu button / confirm (stroke
memorisation)
7
Button for door opening / increased value
8
Display
The procedures and adjustments can only
be carried out when the display is in mode
A, B or C.
[6] and [7] keys simultaneously for
, the