Nice ANATEL Guarita IP Instrucciones Y Advertencias Para La Instalación Y El Uso página 134

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11.9 A09 - FILT EVT EX (EXTERNAL EVENTS FILTER)
The "Filt EVT Ext - External Events Filter" is used to filter the
events information sent through USB Device and primary TCP/IP
to a dedicated PC Software or a monitoring center. If this function
is enabled, only the selected events will be sent.
To change the setting, access the "A09 - Filt Evt Ext (External
Events Filter) option", image 11.9.a, select the events, image
11.9.b, with the options: "Todos os eventos" (padrão) - "All the
events"
(standard),
(acionamentos de dispositivos cadastrados) - "Except apartment
events" (registered devices activation) or "Apenas não atendidos"
(desperta porteiro ou pânico não atendido) – Only not answered
(wake up doorman or not answered panic). Press ENTER to save
the setting.
NOTE: The filtered events in real time will be registered in the Guarita IP internal memory
and can be accessed as event reports.
11.10 A10 - TEMPO EVTS (EVENTS TIME)
The "A10 - Tempo EVTs" option defines the sending of events by
packages and / or by defined time through the USB Device port or
primary TCP/IP. The quantity of events sent by packages (Events)
can help low performances connections, sending a big quantity of
data for each transmission, for example, through a GPRS modem
(consult us for more information). The time setting (Minutes) defines
the maximum time to send the event packages, so even if the
defined quantity has not been reached, when the timeout is finished,
the event package will be sent.
A package can be defined with the quantity from 1 to 67 events,
and the sending interval up to 99 minutes, image 11.10.b.
To change the setting, access the "A10 - Tempo EVTS" option,
image 11.10.a, adjust the desired parameters and press ENTER to
save the setting.
NOTE: The "A10 - Tempo EVTs" menu setting implies time of
sending events to the Linear-HCS Software and others. To send
the events in real time, define the parameters as "0 Eventos" and
"0 Minutos", image11.10.c.
"Exceto
eventos
de
apartamentos"
Image 11.9.a
Image 11.9.b
Image 11.10.a
Image 11.10.b
Image 11.10.c
Português -
English - 134
134

Publicidad

Tabla de contenido
loading

Tabla de contenido