14. Advanced control panel

Pump variant
Fitted as standard
TPE3, TPE3 D
TPE2, TPE2 D
6
Fig. 30 Advanced control panel
Option
-
-
1
2
3
4
5
Pos.

Symbol Description

Grundfos Eye
Shows the operating status of the pump.
1
For further information, see
section
21. Grundfos
2
-
Graphical color display.
3
Goes one step back.
Navigates between main menus, displays and
digits.
When you change the menu, the display
always shows the top display of the new
menu.
Navigates between submenus.
Changes value settings.
Note: If you have disabled the possibility to
make settings with the Enable/disable settings
function, then you can enable it again
temporarily by pressing these buttons
simultaneously for at least 5 seconds. See
section
17.35 "Buttons on product"
4
(Enable/disable
Saves changed values, resets alarms and
expands the value field.
Enables radio communication with Grundfos
GO and other products of the same type.
When you try to establish radio communication
between the pump and Grundfos GO or
another pump, the green indicator light in
Grundfos Eye flashes. A note also appears in
the pump display stating that a wireless device
wants to connect to the pump. Press
pump control panel to allow radio
communication with Grundfos GO and other
products of the same type.
Makes the pump ready for operation, and
starts and stops the pump.
Start:
If you press the button when the pump is
stopped, the pump only starts if no other
functions with higher priority have been
5
enabled. See section
Stop:
If you press the button when the pump is
running, the pump is always stopped. When
you stop the pump via this button, the
appears in the bottom of the display.
6
Goes to the Home menu.
Eye.
settings).
on the
20. Priority of
settings.
icon
23