34. Other technical data

EMC (electromagnetic compatibility)
Standard used: EN 61800-3.
The table below shows the emission category of the motor.
C1 fulfils the requirements for residential areas.
Emission category
Motor size
[hp] ([kW])
1450-2000 min
0.33 (0.25)
C1
0.50 (0.37)
C1
0.74 (0.55)
C1
1.0 (0.75)
C1
1.5 (1.1)
C1
2.0 (1.5)
C1
3.0 (2.2)
C1
Enclosure class
Standard: IP55 (IEC 34-5).
Optional: IP66 (IEC 34-5).
Insulation class
F (IEC 85).
Standby power consumption
5-10 W.
Cable entries
Motor size
Number and size of cable entries
[hp] ([kW])
0.33 - 3.0
(0.25 - 2.2)

34.1 Torques

Terminal
Thread size
L1, L2, L3, L, N
NC, C1, C2, NO
M2.5
1 to 26 and A, Y, B
-1
2900-4000 min
-1
-1
4000-5900 min
C1
C1
C1
C1
C1
C1
C1
4 x M20
Max. torque
[lbf-ft (Nm)]
M4
1.73 (2.35)
0.4 (0.5)
M2
0.4 (0.5)

34.2 Sound pressure level

Pump type
TPE2/TPE3 32-80
TPE2/TPE3 32-120
TPE2/TPE3 32-150
TPE2/TPE3 32-180
TPE2/TPE3 32-200
TPE2/TPE3 40-80
TPE2/TPE3 40-120
TPE2/TPE3 40-150
TPE2/TPE3 40-180
TPE2/TPE3 40-200
TPE2/TPE3 40-240
TPE2/TPE3 50-60
TPE2/TPE3 50-80
TPE2/TPE3 50-120
TPE2/TPE3 50-150
TPE2/TPE3 50-180
TPE2/TPE3 50-200
TPE2/TPE3 50-240
TPE2/TPE3 65-60
TPE2/TPE3 65-80
TPE2/TPE3 65-120
TPE2/TPE3 65-150
TPE2/TPE3 65-180
TPE2/TPE3 65-200
TPE2/TPE3 80-40
TPE2/TPE3 80-110
TPE2/TPE3 80-120
TPE2/TPE3 80-150
TPE2/TPE3 80-180
TPE2/TPE3 100-40
TPE2/TPE3 100-120
TPE2/TPE3 100-150
TPE2/TPE3 100-180
Sound pressure level
ISO 3743
[dB(A)]
55
60
65
66
66
52
59
60
63
65
66
48
56
60
60
63
64
66
44
51
59
60
62
62
43
53
53
62
64
43
53
62
64
69