Manitou MRT-X 3255 PLUS Manual De Instrucciones página 264

Tabla de contenido

Publicidad

Signals
The green LED does not switch on when
the START pushbutton is pressed, even
though both the battery and the S-KEY
are inserted.
The green LED blinks fast.
The red LED switches on for 2 seconds and
then the unit switches off.
The red LED blinks once during start up.
The red LED blinks twice during start up. At least one of the actuators correspon-
The red LED blinks three times during
start up.
The red LED blinks four times during start
up.
Signals
The LED POWER is off.
The POWER LED is on.
The ALARM LED
blinks once.
The ALARM LED
blinks twice.
The ALARM LED
blinks three times.
The ALARM LED is on.
The RUN LED blinks.
The ERR LED blinks.
EN
Malfunction signalled by the transmit-
ting unit (Pushbutton)
Identify the radio remote control malfun-
ction according to the light signals on the
units. If the problem persists after the sug-
gested solution has been carried out,
contact the support service of MANITOU
Possible reason
The battery is flat.
No radio link.
The transmitting unit does not work cor-
rectly.
The STOP pushbutton is locked or dama-
ged.
ding to commands is activated or dama-
ged.
The battery is flat.
At least one of the actuators correspon-
ding to commands is activated or dama-
ged.
Malfunction signalled by the receiving
unit (Pushbutton)
Identify the radio remote control malfun-
ction according to the light signals on the
units. If the problem persists after the sug-
gested solution has been carried out,
contact the support service of MANITOU
Possible reason
The receiving unit is switched off.
No radio link.
Error on the STOP outputs.
Error on the SAFETY outputs.
Error on the outputs corresponding to
direction commands.
The receiving unit
does not work correctly.
The receiving unit does not send com-
mands in the CAN network.
CAN communication error.
3-92
ES
Solutions
Replace the battery with a charged
one.
Bring the transmitting unit close to the
receiving unit.
Contact the support service MANITOU.
Unlock the STOP pushbutton.
If this signal persists, contact the support
service MANITOU.
Bring the actuators to the rest position.
If this signal persists, contact the
support service MANITOU.
Replace the battery with a charged
one.
Bring the actuators to the rest position.
If this signal persists, contact the support
service MANITOU.
Solutions
Make sure that fuse F2 is intact.
Correctly plug in the connecting plug
and power on the receiving unit.
Bring the transmitting unit close to the
receiving unit.
Make sure that fuses F3 and F4 are
intact.
Correctly plug in the connecting plug.
Make sure that the STOP outputs are
wired correctly.
Make sure that fuses F1 and F5 are
intact. Correctly plug in the connecting
plug. Make sure that the SAFETY outputs
are wired correctly.
Contact the support service of the
machine manufacturer.
Make sure that the outputs of direction
commands are wired correctly.
Contact the support service of the
machine manufacturer.
Contact the support service MANITOU.
Contact the support service MANITOU.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mrt 3255 plus

Tabla de contenido