10. Technical Service
DANGER
Risk of death to patients and users in case of malfunction and/or fail-
ure of protective measures!
►
Do not perform any servicing or maintenance work under any cir-
cumstances while the product is being used on a patient.
►
Do not modify product.
CAUTION
Modifications of medical devices may result in a loss of potential
guarantee/warranty claims and forfeiture of applicable licenses.
►
Do not modify the product.
►
Contact national B. Braun/Aesculaprepresentative for service and
repair.
Modifications carried out on medical technical equipment may result in
loss of guarantee/warranty rights and forfeiture of applicable licenses.
►
For service and repairs, please contact your national B. Braun/Aesculap
agency.
Service addresses
Aesculap Technischer Service
Am Aesculap-Platz
78532 Tuttlingen / Germany
Phone:
+49 (7461) 95 -1601
Fax:
+49 (7461) 14 -939
E-Mail:
ats@aesculap.de
Other service addresses can be obtained from the address indicated above.
11. Accessories/Spare parts
Art. no.
Designation
GA344244
Kirschner wire protection sleeve
GA344211
Rinsing adapter
GB072R
ECCOS winding aid for cables and hoses
GB073R
ELAN 4 electro ECCOS motor cable
GB262R
ECCOS tray with fixations for GA844
GB600
STERILIT Power Systems oil spray
GB600880
Oil spray adapter for GA344/GA844
TA011944
Cleaning brush
GB482R
ECCOS fixation for GA344/GA844
TA014401
Instructions for use for ELAN 4 electro control unit
GA800 (A4 for ring-binder)
TA014436
Instructions for use for ELAN 4 electro drill tool
GA844 (A4 for ring-binder)
TA014437
Instructions for use of ELAN 4 electro drill GA844
(flyer)
TA014452
Instructions for use for attachments for the small
drill tool GA344 and the drill tool GA844 (A4 for
ring-binder)
TA014453
Instructions for use for attachments for the small
drill tool GA344 and the drill tool GA844 (flyer)
12
12. Technical data
12.1 Classification acc. to Directive 93/42/EEC
Art. no.
Designation
GA844
ELAN 4 electro drill
12.2 Performance data, information about standards
Max. power
Speed
Rotational direction
Cannulation
Weight
Cable length
Dimensions (L × W × H)
Applied part
EMC
Conforming to standard
After 350 preparatory cycles, the product was tested by the manufacturer
and passed.
12.3 Short-time interval operation
Drilling (clockwise/counterclockwise rotation):
■
60 second application, 60 second pause
■
6 repetitions
■
30 min cooling time
■
Max. temperature 48 °C
Medullary reaming (clockwise/anti-clockwise rotation):
■
30 second application, 30 second pause
■
8 repetitions
■
30 min cooling time
■
Max. Temperature 48 °C
Drilling (oscillation):
■
15 s application, 15 s pause
■
3 repetitions
■
30 min cooling time
■
Max. temperature 48 °C
Saw operation with GB891R:
■
30 second application, 60 second pause
■
4 repetitions
■
30 min cooling time
■
Max. Temperature 48 °C
Saw operation with GB892R:
■
30 second application, 60 second pause
■
5 repetitions
■
30 min cooling time
■
Max. Temperature 48 °C
Screws with GB896R and GB897R:
■
10 s machine application, 10 s manual application, 30 s pause
■
30 repetitions
■
30 min cooling time
■
Max. Temperature 48 °C
approx. 200 W
0 rpm to max. 1,250 rpm ± 5 %
Right and left rotation, oscillation
3.3 mm
0.8 kg ± 10 %
4 m ± 10 %
122 × 130 × 27 mm ± 5 %
Type BF
IEC/DIN EN 60601-1-2
IEC/DIN EN 60601-1
Class
IIa