5 Technical data

FlexFilter EX
Max operating airflow
Max vacuum
Process air (dry) temperature
Operating temperature
Main Filter area
Main Filter material
Control Filter area
Control Filter material
Control Filter pressure switch pre-
set
Compressed air quality:
Required air pressure
Max air consumption (intermit-
tent)
Connection
Control voltage
Internal fuse/s (fast-acting)
Control signal fuse (max)
Dimensions
Dimension inlet
Dimension outlet
Weight dust separator (approx)
Weight legs High Stand
Weight legs Extra High Stand
Weight deflector
Weight service platform including
ladder
Max load on the service platform
Area relief panel
FlexFilter EX
Single
1600 m /h (942 cfm)
-50 kPa (-7.25 PSI)
0 - 60°C (32 - 102°F)
-10 - +40°C (14 - 104°F)
x12 m (1x129 sqft)
Conductive (<10ˆ8 ) polyester
x12 m (1x129 sqft)
Polyester
4 kPa (0,58 PSI)
Clean dry, ISO 8573-1 class 5
6 - 10 bar (87 - 145 PSI)
700 N-Litres/min (25 cfm)
Hose nipple 12 mm (1/2 in)
24 V DC ± 10%
250 mA (5x20)
5 A
See
Figure 3a
A-F
Flanged Ø 150 mm (5.9 in)
x Ø 203,2 mm (8 in)
450 kg (992 lb)
108 kg (238 lb)
131 kg (289 lb)
x11 kg (1x24,25 lb)
100 kg (221 lb)
400 kg (882 lb)
x0,096 m (1x1,03 sqft)
Twin
3200 m /h (1884 cfm)
x12 m (2x129 sqft)
x12 m (2x129 sqft)
1400 N-Litres/min (50 cfm)
Flanged Ø 200 mm (7.87 in)
x Ø 203,2 mm (8 in)
850 kg (1874 lb)
113 kg (249 lb)
135 kg (298 lb)
x11 kg (2x24,25 lb)
130 kg (286 lb)
x0,096 m (2x1,03 sqft)
EN