xFUME POWER 350
Tab. 1
Pos. Name
E
F
G
H
I
J
K
L
Control box control elements
<Gas test/load> button
<Wire infeed/store> button
<MIG/electrode/WIG> button
<Material/auto/manual> button
Right-hand knob
Left-hand knob
<Fx> button
<Operating mode> button
Function
If the button is pressed for less than 0.5 s, programs can be
accessed and loaded.
If the button is pressed for longer than 1 s, the gas valve
opens for 20 s and closes automatically. Repeatedly
pressing the button cancels the gas test.
The welding wire is fed at the set wire feed speed for as long
as the button is pressed.
Pressing the button repeatedly switches between the welding
modes. The appropriate LED lights up.
If the button is pressed for less than 0.5 s, the knob can be
used to select the material type. The material type is shown
on the left-hand display. The current selection on the display
is adopted.
If the button is pressed for longer than 1 s, repeatedly
pressing it switches between manual and automatic mode.
The appropriate LED lights up.
 7.4 Setting automatic/manual mode on page EN-26
After pressing the relevant button, the knob can be turned to
set the welding voltage, functions, options, material thickness,
or other parameters in the middle and right-hand displays.
After pressing the relevant button, the knob can be turned to
set the material type, wire feed speed (manual mode), arc
length correction (automatic mode), or other parameters on
the left-hand display.
If the button is pressed for less than 0.5 s, the welding
parameters (e.g. throttle strength) can be set. If the button is
pressed for longer than 1 s, options can be set.
Repeatedly pressing the button switches between 2-step
mode, 4-step mode, 2-step spot welding, and crater filling.
The appropriate LED lights up.