xFUME POWER 350
The control system can be unlocked again as follows:
Repeatedly press the <Fx> button until <CODE> appears on the display.
4
Turn the left-hand knob to select the set unlocking number.
5
Press the <Wire feed> button to unlock the control system.
6
7.14 Feeding the welding wire
Risk of injury from pointed welding wire
If the pointed welding wire is fed, severe puncture injuries may result.
► Do not look directly into the opening of the contact tip to check the wire feed.
► Keep your face and limbs at a safe distance from the wire guide.
7.15 Adjusting the wire spool brake
The wire mandrel comes with a wire spool brake that prevents the wire spool from keeping running when
the wire feed motor stops.
7.16 Performing a gas test
WARNING
Press the torch trigger or the <Wire feed> button on the
1
wire feed unit's control box until the welding wire is fed
through the welding torch cable assembly.
Open the wire feed unit's cover.
1
 7.2.1 Opening and closing the wire feeder's cover on
page EN-22
Adjust the braking effect of the wire spool brake by
2
turning the wire mandrel's hexagon socket screw. Only
tighten the wire mandrel's hexagon socket screw enough
to prevent the welding wire from slipping.
Close the wire feed unit's cover.
3
 7.2.1 Opening and closing the wire feeder's cover on
page EN-22
► Press the <Gas test> button on the control box.
The gas valve opens for 20 seconds and closes
automatically. Alternatively, press the <Gas test> button
again to cancel the gas test.
7 Operation
EN - 29