7 Operation
7.11 Setting the welding torch type and earth cable
Open the options menu.
1
Select the option parameter <tch> (torch).
2
The welding torch type and cable assembly length are displayed as values on the middle display.
1 = gas cooled
2 = liquid cooled
Example: <204> = water-cooled welding torch with a 4 m cable assembly
Turn the right-hand knob to select the welding torch type and the length of the cable assembly.
3
Select the option parameter <cbl> (cable).
4
Turn the right-hand knob to set the total length of the earth cable. The value is displayed on the right-hand
5
display.
To save the settings, press the <Wire feed> button. Alternatively, the setting is automatically saved after
6
20 s and the display switches back to the main menu.
7.12 Managing jobs
7.12.1 Accessing and saving jobs
Up to 100 jobs can be stored in the control box.
Press the <Gas test/load> button to access the job menu.
1
<Job> appears on the left-hand display. The job number appears on the right-hand display. The status of the
memory location appears on the middle display:
<free>
<used>
<==>
► Turn the right-hand knob to select the desired memory location.
► Press the <Wire feed> button to save the current settings.
► Press the <Gas test/load> button to load a previously saved job.
► To overwrite a memory location, press and hold the <Wire feed> button for more than 1 s.
7.12.2 Deleting jobs/factory settings
The control system can be used to delete all jobs saved by the user or to perform a factory reset on the entire
control system.
Deleting jobs
Press and hold the <Fx> button> until <EC1> appears on the left-hand display.
1
Repeatedly press the <Fx> button until <rES 1 -Job> appears on the display.
2
Press and hold the <Gas test> button until <clr> disappears from the right-hand display. The jobs have
3
been deleted.
Factory settings
Press and hold the <Fx> button> until <EC1> appears on the left-hand display.
1
Repeatedly press the <Fx> button until <rES 2 -All> appears on the display.
2
Press and hold the <Gas test> button until <clr> disappears from the right-hand display. The control
3
system has been reset to the factory settings.
7.13 Locking the control system
To prevent third parties from modifying the settings, the control system can be locked.
Repeatedly press the <Fx> button until <CODE> appears on the display.
1
Turn the left-hand knob to select any number between 0001 and 9999.
2
Press the <Wire feed> button to lock the control system. It is now only possible to set the wire feed speed
3
and use the gas test and wire feed functions.
EN - 28
Memory location free
Memory location used
Memory location data currently loading
xFUME POWER 350

Publicidad

loading