7 Operation
7.2.3 Inserting the wire feed rollers
NOTICE
Material damage due to the use of unsuitable wire feed rollers
If the wire electrode and wire feed rollers are not compatible, this can result in heavy abrasion on the
welding wire. This can cause the Teflon core to become clogged or damaged and the welding wire not
to be optimally fed.
► Observe the shape of the grooves and the wire diameter. Wire electrodes and wire feed rollers must
► Always replace the wire feed rollers in pairs.
EN - 24
be compatible.
Fold both pressure levers (I) down.
1
Loosen and remove the knurled screws (G).
2
Fold down the guard plate and remove the lower wire
3
feed rollers (F).
Insert wire feed rollers (F) with a suitable groove for the
4
required welding wire diameter with the wire diameter
information visible. Ensure that the groove is aligned with
the wire feed tube (H).
Fold up the guard plate and tighten the knurled
5
screws (G).
xFUME POWER 350