xFUME POWER 350
10 Faults and troubleshooting
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► The provided filtration system must be used when operating the device.
► The dust collecting container must be closed when operating the device.
► Do not open the dust collecting container until at least one minute has passed since the device was
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
If the device is not automatically ready for use again following a fault, proceed as follows:
Switch off the device.
1
Rectify the fault.
2
Switch on the device.
3
► If the error message still appears after switching the device back on, contact your retailer or
ABICOR BINZEL. Have the fault code to hand.
10.1 Error messages on the control panel
Tab. 10
Code
E02
E11–E14
E24
E80
E81
E88
E91/E92
E94/E95
E96/E97
E99–CAN Communication between the wire feed
WARNING
switched off.
or a damp cloth.
Error messages on the control panel
Cause
Mains voltage too high (> 480 V) or
too low (< 350 V)
Temperature sensors 1–4
interrupted/short-circuited
Incorrect device type set in the
control box
Incorrect software version in the device
or control box
Encoder motor faulty, cable break, or
incorrect motor type set
Control box incorrectly configured,
e.g. double case system
Incorrect data transmission via
CAN line
Incorrect CAN protocol
unit (control box MC) and welding
power source completely
disconnected.
10 Faults and troubleshooting
Description
► Check the mains voltage.
► Check the temperature sensor cables.
► Check the temperature sensors.
► Contact ABICOR BINZEL or a service partner.
► Update the software.
► Check the encoder motor and cable.
► Check the control box to see if the correct motor
type has been set.
► Check the control box configuration.
► Check the CAN line.
► Check the control box configuration.
► Check the welding torch intermediate cable
assembly for cable breakage.
► Check the plug.
► Check the control box MC or control board in
the device.
EN - 37