Descargar Imprimir esta página

Abicor Binzel xFUME POWER 350 Manual De Instrucciones Original página 69

Publicidad

Idiomas disponibles

Idiomas disponibles

xFUME POWER 350
7.2.2 Installing the wire spool
 Fig. 9 Wire feeder on page EN-22
The device is not supplied with a wire spool and must be fitted with one before the welding process starts.
The welding wire used depends on the workpiece to be welded. When using chromium-nickel welding wire,
the wire guide spiral should ideally be replaced with a Teflon wire guide.
The wire spool holder (B) is optionally placed on the wire
mandrel (C) or provided loose.
If the wire spool holder (B)is placed on the wire
1
mandrel (C), squeeze the wire spool holder (B) and
remove it from the wire mandrel (C).
Place the wire spool on the wire mandrel (C) so the wire
2
uncoils clockwise.
The wire mandrel (C) has a locking bolt on it. Place the
3
wire spool on the mandrel in such a way that the locking
groove on the wire spool adapter (J) sits on the locking
bolt.
Lock the twist locks (E) (2×).
4
Squeeze the wire spool holder (B) and place it on the
5
wire mandrel (C).
Push the welding wire through the wire guide tube (H).
6
Close the wire feeder's cover.
7
 7.2.1 Opening and closing the wire feeder's cover on
page EN-22
The welding wire is fed in accordance with:
 7.14 Feeding the welding wire on page EN-29
7 Operation
EN - 23