Connection Color Coding; Connection Legend - Kübler Sendix 5814FS2 Manual De Instrucciones

Ocultar thumbs Ver también para Sendix 5814FS2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• If shielding is not possible, appropriate filtering measures
must be taken.
• If the protective earth should be connected to the shield on
one side only, it must be made sure that no short-time over-
voltages can appear on the signal and supply voltage lines.
Unused signals
• Connect the input to 0 V (ground GND) if the input signals
(SET, DIR) are not used.
Kübler offers a wide range of connection cables in various
versions and lengths, see
technology
.
Kübler offers various solutions for EMC-compliant installation,
e.g. shield terminals for the electrical cabinet, see
www.kuebler.com/accessories

4.2.3 Connection Color Coding

Part of the cables are identified by a color coding, part of
them by a numerical coding.
Abbreviation of the colors:
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 03
www.kuebler.com/connection
.
Abbreviation Color
WH
White
BN
Brown
GN
Green
YE
Yellow
GY
Gray
PK
Pink

4.2.4 Connection Legend

+V
Encoder supply voltage +V DC
0V
Encoder ground GND (0V)
A, /A
Cosine signal
B, /B
Sine signal
C+, C-
Clock signal
D+, D-
Data signal
SET
Set signal
DIR
Direction signal
Connector housing (cable shield is applied on the
PH
connector housing), protective earth
Abbreviation Color
BU
Blue
RD
Red
BK
Black
VT
Violet
GY-PK
Gray-Pink
RD-BU
Red-Blue
EN - 53

Publicidad

Tabla de contenido
loading

Tabla de contenido