Failure exclusion coupling element
A safe mechanical connection of the encoder is necessary.
Standard EN 61800-5-2 defines the loosening of the mechan-
ical connection (between the encoder and the drive) as a as a
fault that requires consideration. Fault exclusion is required
for the coupling elements if the control cannot detect this
fault.

4.1.3 Dimensions and Details

Reference to the data sheet
The technical drawing with complete dimensioning can be
found in the data sheets of the corresponding variant of the
device.
The illustrations below only show a selection of examples. All
values without unit in the picture are given in mm [inch].
In order to simplify the drawings and information, unless oth-
erwise specified, the general tolerances with tolerance class
m (medium) according to ISO 2768-1 apply.
46 - EN
NOTICE
NOTICE

4.1.3.1 Solid Shaft Encoders

Di-
5814FS
men-
Incremental
sion
a
38 [1.50]
D = Shaft dia-
meter
10 [0.39]
Clamping flange, solid shaft with key
3xM3, 6 [0.24] deep
3xM4, 8 [0.32] deep
Feather key DIN 6885 - A - 3x3x6
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 03
5853FS
5863FS
Singleturn Ab-
Multiturn Abso-
solute
lute
38 [1.50]
49.5 [1.95]
Shaft fit
L = Shaft length