Connecting The Connecting Wires; Commissioning And Operation; General Information For Commissioning; Operational Readiness When Switching On - Kübler Sendix 5814FS2 Manual De Instrucciones

Ocultar thumbs Ver también para Sendix 5814FS2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

In-
Type
M23 connector, 12-pin
ter-
of
face
con-
nec-
tion
3, 4
3, 4
Sig-
0V +
nal:
V
Pin:
1
2 3 4 5 6
Sig-
DI
A /A B /B
nal:
R
Pin:
8
9 1

4.2.7 Connecting the Connecting Wires

• When connecting the connecting wires, check the proper
presence of the supply voltage and the proper functioning.
• If the supply voltage is reversed, the encoder does not func-
tion.
• Check the proper presence of the sine and cosine signals
and their amplitude level, polarity and phase position.
• In the event of an error in the SinCos path, the function
2
2
sin
(x) + cos
(x) = 1 is no longer fulfilled or the rotation direc-
tion is wrong, e.g. due to the reversing of sine and cosine
(wrong phase position).
Detailed information on the connection can be found in the
product data sheets.
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 03
Connector
C
C
D
D
SE
9
1
+
-
+
-
T
2
7
10
3
11
4
1
1
P
0
1
2
H

5 Commissioning and Operation

5.1 General Information for Commissioning

Status LED (optional)
The LED (red) displays various alarm and error messages.
8
The LED is off in normal operation. A lighted LED (status out-
7
put LOW) indicates:
12
• Sensor error, singleturn or multiturn (soiling, glass break-
6
5
age, etc.).
• LED error, failure or aging.
• Over or undertemperature
• Please not that in SSI mode the error indication can only be
reset by switching off the voltage supply.
• The indications are not safety-assessed and serve only for
diagnosis.

5.2 Operational Readiness when Switching On

The sine and cosine signals are immediately available after
switching on the voltage supply.
Wait at least 150 ms until the encoder is ready for operation,
that is to say until the interfaces are ready for communication.
The encoder will communicate with the outside through the
digital interface only after this period.
EN - 55

Publicidad

Tabla de contenido
loading

Tabla de contenido