7. THERMOREGULATOR "SMART MT"
SERVICE SECTION PARAMETER LIST
Menù
Par
label
DHW Domestic hot water production settings
H701
Setting the time of the first DHW request
C701
Setting of set temperature of the first DHW request
H702
Setting the time of the second DHW request
C702
Setting of the set temperature of the second DHW Request
Setting of the set temperature of the DHW maintenance
C703
NOTE: Start DHW production when L164 (domestic temp.) < C703
Differential setting on the set temperature of the DHW maintenance NOTE: Stop
C704
DHW production when L164 (domestic temp.) C703 + C704
Target temperature setting for compressor adjustment during DHW production
C705
(L561)
C706
Setting the DHW accumulation loading speed with the PdC
L706
DHW accumulation loading speed with Eco Hot Water
700
Delay time setting to activate the electric heater as an addition to DHW production
C707
(L248)
Set temperature setting for the electric heater as an addition to DHW production
C708
(L248)
Exchange power setting (negative sign = input power) to activate the Electric
C709
Heater as an addition to the DHW production (L248)
Setting the frequency with which to carry out the heat treatment of the DHW
C710
(L249).
NOTE: 0=disabled.
C711
Setting of the Set temperature for heat treatment of DHW (L249)
C712
Setting of the DHW heat treatment duration
C713
Setting the time at which to perform the heat treatment of the DHW
Frost protection settings
Setting of the external temperature under which the 1st level Freeze Protection
C801
Function is activated (L241)
Setting of the PdC inlet/outlet water temperature under which the 1st level Freeze
C802
Protection Function is activated (L241)
800
Setting of the PdC inlet/outlet water temperature under which the 2nd level Freeze
C803
Protection Function is activated (L242)
C804
Differential setting to exit frost protection
Additional heater settings
Target Delta setting not met: target temperature differential (L560) to activate
C901
additional heater (L245)
C902
Delta target delay time setting not met to activate additional heater (L245)
Setting of the bivalence external temperature under which
C903
the additional heater is activated (L245)
C904
Setting of the bivalence external temperature differential
900
C905
Unit cost of electricity
L905
Cost of electricity
C906
Unit fuel cost for additional heater
L906
Cost of electricity for the additional combustion heater
C907
Efficiency of additional combustion heater
C908
Power of the additional electric heater
Description
Software version 4.11
Range
U. m.
Default
min
max
h:min
0
H702
07:00
°C
30.0
55.0
45.0
h:min
H701
23:59
18:00
°C
30.0
55.0
55.0
°C
30.0
55.0
35.0
°C
2.0
5.0
20.0
°C
50.0
60.0
60.0
°C/h
1.0
60.0
3.0
°C/h
Reading
min
0
120
0
°C
30.0
60.0
55.0
kW
0
-6.00
-1.60
days
0
30
0
°C
50.0
70.0
60.0
min
1
30
15
h:min
00:00
23:59
02:00
°C
-20.0
5.0
3.0
°C
-20.0
5.0
2.0
°C
-20.0
1.0
1.0
°C
1.0
10.0
3.0
°C
2.0
4.0
2.0
min
30
120
60
°C
-20.0
30.0
-20.0
°C
1.0
30.0
5.0
€ / kWh
0
1.00
0.20
€ cent
Reading
€ / kWh
0
1.00
1.00
€ cent
Reading
%
50
100
95
kW
1.00
10.00
1.50
EN
EN
Register
PW
(Base 0)
59
16493
59
16494
59
16495
59
16496
-
16497
-
16498
59
16499
59
16500
59
9057
59
16501
59
16502
59
16525
59
16503
59
16504
59
16505
59
16506
59
16509
59
16510
59
16511
59
16512
59
16524
59
16533
59
16531
59
16532
59
16534
59
9055
59
16535
59
9056
59
16536
59
16559
125