5. INSTALLATION
1. DESCRIZIONE DEI COMPONENTI
5.5 Electrical System
Make sure that the general power supply has been turned off. Never touch
the electrical components immediately after removing the power supply,
always wait at least 5 minutes .
WARNINGS
• The electrical connections must be carried out by qualified personnel
and in compliance with the regulations in force in the place of instal-
lation.
• The connection must be preceded by an accurate check of compa-
tibility between the power supply line and the characteristics to be
connected.
• The unit must be connected to an impedance electrical network
0,354
• Make sure to use a dedicated power supply only for the heat pump.
• The heat pump power cables must have a section equal to or greater
than that indicated in the following table. The supply cable must com-
ply with the IEC standard. (60245 IEC57 (H05RN-F)
• In the power supply line of the unit it is mandatory to provide a diffe-
rential / magnetothermal switch with a contact separation of at least
3 mm in each pole, with a maximum trip threshold of 30 mA, sized
according to the table:
Model
Supply cable (mm
EH0618DC
2,5
EH1018DC
4
EH1218DC
4
EH1618DC
6
EH1718D3
2,5
*If combining the MIRAI SMI heat pump with the Eco Hydro Kit, refer to
the Eco Hydro Kit manual
Distribution
Panel
Connect the Earthing Cable
The earthing cable must not be connected to the piping, the
gas supply, lightening rods or telephone lines; incorrect earth-
ing can cause electrical discharge and damage to the unit.
Capacity of differential
2
)
magneto thermal switch
(A)*
16
20
25
32
16
Magnetothermal /
Differential Switch
By removing the cover of the electrical panel you have access
to the heat pump terminal board and to the PCB-TERMINAL BLOCK.
R1 out
T1 out
T2 out
L1 out
L2 out
P1 in
P0 in
M1 out
M2 out
P2 out
W1 out
U1 out
PCB TERMINAL BlOCK
PCB TERMINAL BLOCK
MORSETTIERA
Grounding wire
Cavo di messa a terra
Power supply cable
Cavo di alimentazione
EN
EN
Internal
Schema
scheme
interno
to the PCB
alla PCB
TERMINAL
TERMINAL
BLOCK
BLOCK
TERMINAL
Cable gland
Pressa cavo
MORSETTIERA
TERMINAL EH1718D3
TRIFASE
L1 L2 L3
Ground wire
Messa a terra
Supply
Alimentazione
Pressa cavo
Cable gland
95