5. INSTALLATION
5.6 Connection specifications Recipe 1 (C400 = 1)
Factory configuration
ELECTRICAL CONNECTIONS TO THE PCB TERMINAL BLOCK
DHW Domestic Hot Water
Sensor
Room
thermostat
On / Off
Compressor frequency
limitation
Summer (open)
Winter (closed)
Set Point 2 consent for Fancoil
Note:
It is possible to connect the FEBOS-CRONO to the RS485- and RS485+ contacts of the TERMINAL BLOCK PCB, to use it as a display panel for the operating parameters of the
heat pump and the system, and to carry out the On/Off and Summer/Winter of the heat pump itself.
To use, it is necessary to configure the FEBOS-CRONO Window Contact as NC (Normally Closed), and make sure that contact 102 on the TERMINAL BLOCK board is jumpered.
To use the FEBOS-CRONO also as a thermostat/humidistat, set a recipe 10, also including the installation of the flow meter.
Consent to Additional
heater
R1 out
T1 out
T2 out
L1 out
Booster Pump
L2 out
P1
in
P0
in
M1 out
M2 out
HP signal in alarm
P2 out
W1 out
U1 out
EN
EN
EN
EN
etiKa Evo
Consent to
ECO HOT WATER
Consent to
3-way DHW valve
97