Wheel Spin; Unbalance Display Without Rounding-Off - SICE S 63 E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Wheel spins take place automatically by lowering the guard or pressing the
the guard lowered.
A special safety device stops rotation if the guard is raised during the spin; in this case, the
"A Cr" message is displayed.
WARNING
To obtain the most accurate results, do not apply any undue stress to the machine during

wheel spin.

CAUTION
Do not operate the machine without the guard and/or if the safety device has been tam-
pered with.
CAUTION
Never raise the guard before the wheel has come to a stop.
CAUTION
If the wheel keeps spinning permanently due to a fault on the machine, switch off the ma-
chine using the main switch or disconnect the plug from the power supply board (emergency
stop) and wait until the wheel stops before raising the guard.
If the
key is pressed whilst the wheel is rotating, the spin will be prematurely interrupted.
7. UNBALANCE DISPLAY WITHOUT
When started up, the machine is set to display the unbalance values at five-gramme
increments, i.e. rounded to the nearest multiple of five (or quarters of an ounce if visu-
alised in ounces).
In this condition, the first four grams of unbalance are not displayed since an appropriate
threshold, indicated by illumination of the
The
key can be pressed to temporarily eliminate the threshold (the LED "g x
5"; "oz x 1/4" goes out) and the unbalance values will be displayed gram by gram (or in
tenths of an ounce if display in ounces is active).
Operator's Manual S 63 E - S 63 E C
6. WHEEL SPIN
ROUNDING-OFF
LED on the display panel, is activated.
key with
105

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S 63 e c

Tabla de contenido