Roger Technology B70/1DCHP Instrucciones Y Advertencias Para El Instalador página 60

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 148
CONTACT
25(AP)
23(COM)
26(CH)
23(COM)
27(PP)
23(COM)
28(PED)
23(COM)
29(+24V)
30(COM)
31(LAM)
30(COM)
ENC
FC
SB
RECEIVER CARD
BATTERY CHARGER
B71/BCHP
BATTERY KIT
2x12 Vdc 4,5 Ah
Only AGM type
60
DESCRIPTION
Open control signal input (N.O.).
IMPORTANT: persistent activation of the opening command prevents automatic reclosure; the
automatic reclosure time count is resumed when the opening command is released.
Close command input (N.O.).
Step by step mode command input (N.O.).
The function of the control is determined by parameter
Partial open control signal input (N.O.).
Set by default to 50% of completely open position.
Power feed for external devices. See technical characteristics.
Connecting B72/BRAKE/2 power unit for BG30 High Speed versions.
Connection for ashing light (24 Vdc - duty cycle 50%).
The settings for the pre-manoeuvre ashing warning signal may be selected with parameter
while the ashing mode is set with parameter
Connector for connecting to encoder installed on motor.
WARNING! Always disconnect from electrical power before disconnecting or connecting the
encoder cable. N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C. contacts) for connecting mechanical limit switch (see gure 14 - detail B)
or magnetic limit switch (see gure 15 - detail C). The gate stops when the limit switch is
activated.
Adjust the limit switches so that, once triggered, the gate stops slightly before it reaches the
mechanical stop. IMPORTANT: repeat the travel acquisition procedure after each adjustment
to the limit switches.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C.) for connecting release contact. If the motor release handle is opened, the
gate stops and no command signals are accepted.
Once the release handle is closed again and the key turned to the close position, if the gate
is in an intermediate position, the control unit initiates the position recovery procedure (see
chapter 20).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector for plug-in radio receiver board.
The control unit has two radio remote control functions by default:
– PR1 - step mode command (modi able with parameter 76).
– PR2 - partial opening command (modi able with parameter 77).
The programming buttons PR1 and PR2 are also accessible with the cover closed (see gure 10).
Connector for slot-in battery charger board.
In the event of a mains power loss, the controller unit is powered by the batteries. When battery
power is used, the message
at intervals until mains power is restored or until the battery voltage drops below the minimum
permissible limit. In this case,
accepts no commands.
If mains power is lost while the gate is moving, the gate stops and then automatically resumes
the interrupted manoeuvre after 2 seconds.
To reduce battery consumption, the positive power feed wire of the photocell transmitters may
be connected to terminal SC (see g. 6-7-8-9). Set
controller unit disconnects power from the accessory devices when the gate is completely
open or completely closed.
WARNING! the batteries must always be connected to the electronic controller unit in order to
charge. Periodically (at least every 6 months), check that the battery is in good working order.
For more information, refer to the installation manual for the B71/BCHP battery charger.
.
.
is shown on the display and the ashing light ashes brie y
(Battery Low) is shown on the display and the controller unit
or
,
. In this con guration, the

Publicidad

Tabla de contenido
loading

Tabla de contenido