PROBLEM
(EnE5)
The gate does not
open or close.
(btLO)
ashing
Acquisition procedure
does not complete
correctly.
Remote control has
limited range and does
not work while auto-
mated gate is moving.
The ashing light is
not working.
Gate open indicator
lamp does not work.
Gate does not perform
desired manoeuvre.
N.B.: Press the TEST button to temporarily cancel the alarm.
The next time a command is received, the alarm reappears on the display if the problem has not been resolved.
80
ALARM
POSSIBLE CAUSE
Encoder malfunction.
Insu cient power supply
Batteries functioning
Encoder calculation error.
Inverter thermal overload circuit
breaker tripped.
Flat batteries.
Release device open.
Motor calibration failed.
Problems with the encoder cir-
cuit or on the connecting cable.
TEST button pressed accidentally. Repeat acquisition procedure.
Safety devices in alarm state.
Excessive voltage drop.
Incorrect setting of parameters
and
.
Travel length error.
Maximum permitted travel
length exceeded
The radio transmission is im-
peded by metal structures and
reinforced concrete walls.
Flat batteries.
Bulb / LED blown or ashing
light wires disconnected.
Bulb blown or wires discon-
nected.
Incorrect setting of parameter
.
Incorrect selection of the bat-
tery type.
ACTION
Press TEST button. Replace the encoder if the
problem persists.
If the unit contains dirt, moisture, insects or other
foreign matter, disconnect from mains power and
clean the board and the encoder. Replace the en-
coder if the problem persists.
The batteries are almost at.
Repeat acquisition procedure.
Function is restored automatically within 2 min.
Wait for mains power to be restored.
Close the release handle and turn the key to the
close position. Check that the release contact is
connected correctly.
Repeat acquisition procedure.
If the problem persists, check the cable connec-
ting the encoder to the motor.
Check if release handle is open.
Check that the motor turns without impediment. Con-
tact technical support in case of any problems.
Check the good condition of the onnection cable.Di-
sconnect and then reconnect from main power.Give
a command (opening/step-by-step, ... ).
If
does NOT appear, repeat the learning proce-
dure.
If
appears again contact the technical assi-
stance.
Press the TEST button and check the safety
device/s in alarm state and the connections of
the safety devices.
Repeat acquisition procedure.
Check mains voltage.
Adjust parameters
and
weight and speed of the gate leaf.
Move gate into completely closed position (FC
limit switch signal must be active) and repeat the
procedure.
Check cable of limit switches. Replace the cable
if the problem persists.
Reset default controller unit parameters and repe-
at the procedure.
Stroke length less than the minimum allowed:
increase the length
Reduce the ride. Contact technical assistance
(travel exceeding the maximum allowed by the
technical characteristics)
Install the antenna outside.
Replace the transmitter batteries.
Check LED circuit and/or connector wires.
Check the bulb and/or wires.
Select the correct installation position with para-
meter
.
Change the value of the parameter
correctly for the
.