Con guring radio channel 1 (PR1)

Con guring radio channel 2 (PR2)
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
Courtesy light. The output COR is managed from the remote control. The light remains lit as long as the remote
control is active. The parameter
Courtesy light in step mode (PP). The output COR is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
STEP MODE with con rmation for safety.
PARTIAL OPENING with con rmation for safety.
OPENING with con rmation for safety.
CLOSURE with con rmation for safety.
To prevent gate manoeuvres caused by accidentally pressing a remote control button, con rmation is required to enable the
(1)
command. Example: parameters
• Pressing the CHA button on the remote control selects the step mode function, which must be con rmed within 2 seconds by
pressing CHB on the remote control. Press CHB to activate partial opening.

Con guring ashing light frequency

The frequency is set electronically from the ashing light unit.
Slow ash.
Light ashes slowly when gate opens, rapidly when gate closes.
Selecting courtesy light mode
Disabled.
PULSE. The courtesy light illuminates brie y at the start of each manoeuvre.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
Clock contact con guration.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
When the clock function is active, the gate opens and remains open. Any command signal received is ignored.
When the clock function is active, the gate opens and remains open. Any command signal received is accepted.
When the gate returns to the completely open position, the clock function is reactivated.
Enable safeguarded gate closure/opening.
Enabling this parameter ensures that the gate is not left open due to an incorrect and/or accidental command.
This function is NOT enabled if:
• the gate receives a STOP command;
the sensitive edge intervenes, detecting an obstacle in the same direction in which the function is enabled. If instead the
sensitive edge detects an obstacle during the movement opposite to the one guaranteed, the function remains active.
• the number of closure attempts set by parameter
• the acquired position is lost (perform position recovery, see chapter 20).
Disabled. The parameter
Enabled.
After a period of time set with parameter
regardless of the parameter
Enabled.
If the gate is closed as a result of a step mode command, after a period of time set with parameter
unit signals a 5 second warning with the ashing light (regardless of the parameter
If the gate is stopped by the obstacle detection system during a closure manoeuvre, the gate closes after a period
of time set with parameter
If the gate is stopped by the obstacle detection system during an opening manoeuvre, the gate closes after a period
of time set with parameter
N.B.: With ROGER TECHNOLOGY plug-in radio receiver board.
N.B.: With ROGER TECHNOLOGY plug-in radio receiver board.
is ignored.
(1)
(1)
(1)
(1)
and
set:
is not displayed.
, the control unit signals a 5 second warning with the ashing light,
, and then closes the gate.
.
.
is ignored.
has been reached;
, the control
), and then the gate closes.
73