Travel acquisition

For the system to function correctly, the gate travel must be acquired by the control.
11.1

Before starting

1. Select the automation system model installed with the parameter
KEY:
HIGH SPEED Motor
SELECTION
BG30/1600
BG30/2200
BG30/1000/HS
BG30/1400/R
BG30/1800/HS
BG30/1500/HS
2. Select the position of the motor relative to the gate with the parameter
is with the motor installed on the right hand side of the gate (seen from interior side).
OPENING ON THE LEFT
3. Adjust the (mechanical or magnetic) limit switches so that, once triggered, the gate stops slightly before it
reaches the mechanical stop.
CLOSING LIMIT SWITCH
4. Check that the operator present function is not enabled (
OPEN
CLOSE
5. Move the gate into the closed position.
6. Press TEST (see TEST mode in chapter 10) and check the command signal and safety device states. If any
safety devices are not installed, jumper the relative contact or disable the device from the relative parameter
(
,
,
,
,
and
64
REVERSIBLE Motor
MOTOR
MODEL
TYPE
OPENING ON THE RIGHT
OPENING LIMIT SWITCH
).
.
CONFIGURATIONS
-
up to 1600 kg
-
up to 2200 kg
see chapter 14 "Special Parameters for
up to 1000 kg
High Speed Motor"
see chapter 15 "Special Parameters for
up to 1400 kg
Reversible Motor"
see chapter 14 "Special Parameters for
up to 1800 kg
High Speed Motor"
see chapter 14 "Special Parameters for
up to 1500 kg
Reversible Motor"
. The default setting for this parameter
).