Electrical System:
Service laptop connection interface:
– To configure all the key truck data (limit position damping, lift cutout, retardation
and acceleration patterns, cut-outs etc.) rapidly and reliably.
– To read out the error log to analyse fault causes.
– To simulate and analyse program operations.
– Provides simple functional extension by releasing code numbers.
The controller is fitted with a CAN Bus and a continually measuring sensor system.
The controller provides smooth start-up and braking of the load in all limit positions
through limit position and intermediate cushioning.
Highly efficient threephase technology with energy retention for the drive and lift mo-
tors provides high travel and lift speeds and better use of energy.
The MOSFET threephase controller provides smooth starting for all movements.
For drive battery options see section "Battery type" in chapter F.
3
Standard Version Specifications
NOTICE
Technical data specified in accordance with the german standart „Type
sheets for industrial trucks".
Technical modifications and additions reserved.
3.1
Performance data
Q Capacity (where c= 23.6 inch (600 mm))
c Load center of gravity distance
Travel speed without load (RG)
Travel speed with load (RG)
Travel speed without load (WG)
Travel speed with load (WG)
Travel speed without load (FR)
Travel speed with load (FR)
Lift speed without load
Lift speed with load
Lowering speed with load
Lowering speed without load
RG:
Rail Guidance
WG:
Wire Guidance
FR:
Free Range
Description
EKS 314
3000 lbs
1360 kg
23.6 inch
600 mm
6.0 mph
9.6 km/h
6.0 mph
9.6 km/h
4.7 mph
7.5 km/h
4.7 mph
7.5 km/h
6.0 mph
9.6 km/h
6.0 mph
9.6 km/h
1.21 ft/s
0.37 m/s
1.21 ft/s
0.37 m/s
1.15 ft/s
0.35 m/s
1.12 ft/s
0.34 m/s
D 5