At the bottom (4)
• Patient information include:
BED NO
Patient type
"01-01-2005"
"07:11:17"
M
BLOOD
Waveform / Menu Area (2)
The waveform area can maximally display 8 waveforms. The displaying order of the waveforms on the
screen can be adjusted. For the maximum configuration, the waveforms provided by the system for selection
are: 2 ECG waveforms, SpO
All the waveforms in the system are listed out in the "WAVE SETUP" menu. The user may adjust their
displaying positions. The specific method is illustrated in the part: WAVE SETUP.
The name of the waveform is displayed on the upper left part of the waveform. The user may choose ECG
lead based on the requirements. The gain of the channel are also displayed on each ECG waveform. A 1mV
scale bar is also displayed to one side of ECG waveform. The IBP waveform scale can also be selected
according to the actual requirement. In the IBP waveform area, the waveform scale is displayed. The three
dotted lines for each IBP waveform form up to down represent respectively the upper limit scale, reference
scale and lower limit scale. The values of these three scales can be set. The specific method is given in the
part: Measure IBP.
When menu is wanted during screen operation, the menu always occupies the fixed position in the middle
part of the waveform area, therefore part of waveform can not be viewed temporarily. After exiting the menu,
the system will restore the original screen.
The user may set up the rate to refresh the waveform. The method to adjust the refreshing rate of each
waveform is discussed in the setup description of each parameter.
Parameter Area (3)
The parameter area lies to the right side of the waveform area, whose position basically corresponds to the
waveform. The parameters displayed in the parameter area include:
ECG
- Heart rate or pulse rate (unit: beats/minute)
- The ST analyzing result of channel 1 and 2: ST1, ST2 (unit: mV)
- PVCs (unit: times/minute)
NIBP
- From left to right, there are Systolic pressure, Mean pressure and Diastolic pressure (unit: mmHg or kPa)
SpO
2
- SpO
(unit: %)
2
- Pulse Rate (unit: beats/minute) (When "BOTH" item is selected)
IBP
- The blood pressure of channel 1 and 2. From left to right, there are Systolic pressure, Mean pressure and
Diastolic Pressure (unit: mmHg / kPa / cmH2O)
CO2
- EtCO2 (unit: mmHg or kPa)
- INS CO2 (unit: mmHg or kPa)
- AwRR (times/minute)
RESP
- Respiration Rate (unit: times/minute)
TEMP
- Temperature of channel 1 and 2: T1, T2 and the difference between them TD. (unit: °C or °F)
Bed number of patient under monitoring
Three options: Adult, Pediatric, Neonate
Current date
Current time
Patient sex, Male or Female
Patient blood type
waveform, 2IBP waveforms,RESP waveform, CO2 waveform.