1.2 Ajustes del regulador de intensidad
Tabla 1-6
Tabla de adaptación para módulo de potencia 6SN112V–1AV00–0CA1 25/50 A
Servomotor
M [Nm]
[Nm]
1FT...
1FT
M
o
5044–VAK71
1,3
5046–VAF71
2,6
5046–VAK71
2,6
5062–VAG71
2,2
5062–VAK71
2,2
5064–VAC71
4,5
5064–VAF71
4,5
5064–VAG71
4,5
5064–VAK71
4,5
5066–VAC71
6,5
5066–VAF71
6,5
5066–VAG71
6,5
5066–VAK71
6,5
5070–VAF71
3,0
5070–VAG71
3,0
5070–VAK71
3,0
5071–VAC71
4,5
5071–VAF71
4,5
5071–VAG71
4,5
5071–VAK71
4,5
5072–VAC71
10,0
5072–VAF71
10,0
5072–VAG71
10,0
5072–VAK71
10,0
5073–VAC71
7,0
5073–VAF71
7,0
5073–VAG71
7,0
5073–VAK71
7,0
5074–VAC71
14,0
5074–VAF71
14,0
5074–VAG71
14,0
5074–VAK71
14,0
5076–VAC71
18,0
5076–VAF71
18,0
5076–VAG71
18,0
5100–VAC71
10,0
5100–VAF71
10,0
5100–VAG71
10,0
5100–VAK71
10,0
5101–VAC71
15,0
5101–VAF71
15,0
5101–VAG71
15,0
5102–VAA71
27,0
5102–VAC71
27,0
5102–VAF71
27,0
1) El valor indicado es la intensidad máxima permitida de la combinación parte de potencia/motor respectiva. Depen-
diendo de los órganos mecánicos accionados puede ser necesaria una reducción del valor indicado.
VS/1-8
SIMODRIVE 611 Sistema analógico Instrucciones de puesta en marcha (IAA) – Edición 10.00
I [A]
[A]
[r/min]
[r/min]
I
n
n
o
nom
2,3
6000
3,0
3000
4,7
6000
2,7
4000
3,9
6000
2,7
2000
4,1
3000
5,5
4000
8,0
6000
3,9
2000
6,0
3000
7,9
4000
11,6
6000
2,6
3000
3,6
4000
5,3
6000
2,9
2000
4,3
3000
5,2
4000
7,9
6000
6,1
2000
9,1
3000
12,0
4000
17,5
6000
4,3
2000
6,4
3000
8,1
4000
12,5
6000
8,5
2000
13,0
3000
16,5
4000
25,0
6000
11,5
2000
16,5
3000
21,5
4000
6,2
2000
9,2
3000
12,5
4000
18,0
6000
9,4
2000
14,5
3000
17,5
4000
9,9
1200
16,5
2000
25,0
3000
Definición:
o = Interruptor en posición base OFF
x = Interruptor en posición ON
1)
Límite de intensidad
Interruptores
[A]
[A]
I
I
máx
á
2
3
4
5
o
o
x
x
13,0
o
x
o
x
15,0
o
o
x
o
25,0
x
o
x
x
13,0
o
x
x
o
19,5
o
o
x
x
13,0
x
x
x
o
19,5
o
o
x
o
25,0
o
x
o
o
34,0
x
x
x
o
19,5
x
x
o
o
30,5
o
x
o
o
34,0
o
o
o
o
50,0
o
x
x
x
12,0
x
o
o
x
17,0
o
o
x
o
25,0
o
o
x
x
13,0
o
x
x
o
20,5
o
o
x
o
25,0
o
x
o
o
34,0
o
o
x
o
25,0
x
o
o
o
42,5
o
o
o
o
50,0
o
o
o
o
50,0
o
x
x
o
20,5
x
x
o
o
30,5
x
o
o
o
42,5
o
o
o
o
50,0
x
o
o
o
42,5
o
o
o
o
50,0
o
o
o
o
50,0
o
o
o
o
50,0
o
o
o
o
50,0
o
o
o
o
50,0
o
o
o
o
50,0
x
x
o
o
30,5
x
o
o
o
42,5
o
o
o
o
50,0
o
o
o
o
50,0
x
o
o
o
42,5
o
o
o
o
50,0
o
o
o
o
50,0
x
o
o
o
42,5
o
o
o
o
50,0
o
o
o
o
50,0
 Siemens AG 2000 All Rights reserved
10.00
10.00
Ganancia regulador de
intensidad
Interruptores
Kp(I)
Kp(I)
6
7
8
9
x
x
o
o
2,5
o
o
x
o
4,0
x
x
o
o
2,5
x
o
o
x
6,5
x
o
x
o
4,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
x
o
o
2,5
x
x
x
x
11,5
x
x
o
x
8,0
x
o
x
o
4,5
o
o
x
o
4,0
x
x
x
x
11,5
o
o
x
x
9,5
x
o
o
x
6,5
x
x
x
x
11,5
o
o
x
x
9,5
x
x
o
x
8,0
o
o
x
o
4,0
x
x
x
x
11,5
o
o
x
x
9,5
x
o
o
x
6,5
x
x
o
o
2,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
o
x
7,5
x
x
o
o
2,5
x
x
x
x
11,5
x
o
o
x
6,5
x
o
x
o
4,5
x
o
o
o
1,0
o
x
x
x
11,0
x
o
x
o
4,5
x
x
o
o
2,5
x
x
x
x
11,5
x
o
o
x
6,5
x
o
x
o
4,5
x
x
o
o
2,5
o
o
x
x
9,5
x
o
x
o
4,5
x
x
o
o
2,5
x
x
x
x
11,5
x
o
o
x
6,5
x
x
o
o
2,5

Publicidad

Tabla de contenido
loading