Technical information
6. Noise emission
This machine operates at a noise level above 80 dB(a). We
recommend wearing ear protectors at all times to prevent
damage to hearing.
Warning!
Wear ear protection.
7. Aligning / fastening
General information
The machine should be installed on a level, load-bearing
stand with firmly standing feet.
Any machine must be installed in a way that prevents it from
moving about and tipping over.
Note!
Securely installed machines prevent accidents.
8. Connections required
Main power connection
Connection to the electrical power supply is made by
connecting a 16 A plug
en
appropriate fuse protection.
Care must be taken not to damage electrical supply leads.
These must be changed whenever necessary.
Note!
Before plugging in, instruct a qualified electrician to
check the socket.
1
2
116
to a prepared socket
with
2
1
Compressed air connection
The entire machine is connected to a central in-house
compressed air supply system.
The supply line is fitted with a plug-in coupler
The operating pressure must be set to 6 - 7 bar at the
pressure regulator
.
1
This must be checked at the pressure gauge.
Note!
Only feed in dry compressed air as the pneumatic
system is largely operated on unoiled air.
9. Transporting the machine
Space around the machine
This machine must be installed in such a way that the
machine is readily accessible and easy to walk around.
Remove any objects lying about. For safety reasons, always
allow a clearance of at least 1.0 metre around the machine.
Note!
This machine must only be moved with approved and
tested handling and lifting gear.
Make sure this machine stands firmly.
Always observe the accident prevention regulations
applicable to your company.
.
2
1
2