Technical data, relay module UE 10-2OS

Rated coil voltage
Dropout current
Coil resistance
Relay contacts
Switching contacts
Signalling contacts
Contact load capacity
Max. switching voltage
Switching capacity/voltage
Switching current
Max. switch-on current/duration
Release time (use to calculate
response time)
Pickup time
Operating temperature
Enclosure rating
Overvoltage category
Degree of contamination
Connector cross-section
Mechanical life
Electrical life
Fixing rail
Tab. 9-2: Data sheet for relay module
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
24 V DC –30 %/+20 %
4.2 mA
520 Ω ±10 %
2 no
1 + 1 nc
max. 250 V AC
690 VA/230 V AC
72 W/24 V DC
20 mA ... 3 A
max. 15 A/20 ms
≤ 5 ms
≤ 20 ms
–20 °C ... +60 °C
IP 20
3
2
2
0.5 ... 2.5 mm
5 x 10
7
switching cycles
5
1 x 10
switching cycles (load-dependent)
DIN (EN 50022-35)
GB
Chapter 9
3 1 9