SICK LE20 Instrucciones De Operación página 303

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
Operating Instructions
LE 20
Note
Note
8 008 685/Q913/2007-05-21
Product description
optical sensors
inductive sensors
mechanical switches
signals from a control unit
They must, however, have the following technical features:
Voltage supply
Sensor output
Signal level:
– object detected by sensor
– object not detected by sensor
The safety and muting sensors cannot be supplied with power by
the LE 20 safety evaluation unit.
If the wires for the muting sensors are laid outside the control
cabinet, they must be carried in separate sheathed cables
Relay module
The supply connections of the safety evaluation unit have two
semiconductor outputs (max. output current 0.5 A). If the switching
capacity is insufficient or volt free contacts are required, a relay
module with two volt free relay contacts can be connected.
Fig. 3-5: Safety evaluation unit LE 20 with relay module UE 10-2OS
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
24 V DC
PNP (open collector) or relay
high (≥ 15.5 V DC)
low (≤ 10.5 V DC)
UE 10-2OS
9
5 4 3 2 1
GB
Chapter 3
8
7
6
3 0 3

Publicidad

Tabla de contenido
loading

Tabla de contenido