Operating Instructions
LE 20
Safety evaluation unit LE 20 Muting
Pin-No.
Marking
18
LAMP 1
19
LAMP 2
20
Intercon.+
21
Intercon.+
22
CONCURR.
23
SEQUENCE
24
Intercon.+
25
Intercon.+
26
BIT 2
27
BIT 1
28
Intercon.+
29
M 4
30
M 3
31
M 2
32
M 1
Tab. 5-2: Terminal assignment LE 20 Muting, nc = not connected
Number of
CONCURR.
muting sensors
4
nc
nc
Intercon.+
Intercon.+
3
nc
Intercon.+
nc
2
Intercon.+
Tab. 5-3: Configuration of the muting monitoring functions, nc = not connected
8 008 685/Q913/2007-05-21
Electrical installation
Meaning (I = input, O = output)
I: 24 V PNP output for activating muting lamp, I
I/O: 24 V PNP output for activating a redundant muting lamp,
I
= 500 mA. If LAMP 1 only is connected,
max
LAMP 2 must be connected to Intercon.+.
O: Auxiliary control voltage (U
O: Auxiliary control voltage (U
I: Concurrence monitoring, see Tab. 5-3
I: Sequence monitoring, see Tab. 5-3
O: Auxiliary control voltage (U
O: Auxiliary control voltage (U
I: Configuration for respective number of installed muting photoelectric switches:
Bit 1
Bit 2
nc
nc
Intercon.+
nc
nc
Intercon.+
Intercon.+
Intercon.+
O: Auxiliary control voltage (U
I: Muting photoelectric switch 4
I: Muting photoelectric switch 3
I: Muting photoelectric switch 2
I: Muting photoelectric switch 1
SEQUENCE
Muting monitoring:
Muting condition +
nc
Sequence monitoring
Intercon.+
Concurrence monitoring
nc
Sequence monitoring with direction monitoring
Intercon.+
(Muting condition only)
nc
Concurrence monitoring with direction monitoring
Intercon.+
(Only muting condition +) direction monitoring
nc
Concurrence monitoring
Intercon.+
(Muting condition only)
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
= 500 mA
max
)
B
)
B
)
B
)
B
4 sensors
3 sensors
2 sensors
Not permitted
)
B
GB
Chapter 5