Bosch DCI 700 Manual Original página 12

Common-rail injector test bench
Tabla de contenido

Publicidad

en | 12 | DCI 700
3.2
Switching off the DCI 700
1. The "DCI" software and other open applications clo‐
se.
2. Shut down the Windows operating system.
3. Switch off the DCI 700 at the master switch.
After shutting down, wait 30 seconds before
switching the DCI 700 back on.
---Separator---
3.3
Stopping the DCI 700 in the event of
a problem
1. In the event of a problem, stop the test with <Stop>.
 Actuation of the injectors is stopped.
 The drive motor shuts down in a controlled man‐
ner.
 The pressure in the high-pressure rail is released.
2. Rectify the fault.
3. Continue the test or restart.
Switch off the DCI 700 at the main switch only in
an extreme emergency. Switching off by the main
switch while a test is being conducted can dama‐
ge the computer unit or the operating system.
---Separator---
3.4
Testing injectors
DANGER
Touching hot injectors and the hot test acces‐
sories (e. g. the injection chamber) can cause
severe burns.
 Allow injectors and test accessories to cool.
 Put on protective gloves before removing the
injection chamber.
 Connecting and testing injectors (see DCI 700 Help
Center).
---Separator---
3.5
Updating "DCI" software
 Updating software "DCI", see DCI 700 Help Center.
---Separator---
3.6
Opening the DCI 700 Help Center
1. In the "DCI" software, select <?>.
2. Select the "Help Center" tab.
---Separator---
1 689 989 473 | 2020-11-24
3.7
Adjust the height of the HMI
1
3
 21:
Adjust the height of the HMI
(1) Monitor
(2) Locking knob for swivel adjustment
(3) Torx screws for clamping device
(4) Keyboard shelf
(5) Locking knob for swivel adjustment
The monitor or keyboard shelf attached to the
monitor column can drop as soon as the clamping
device for the monitor or keyboard shelf is rele‐
ased. In this case, the monitor or keyboard shelf
could be damaged.
(1)
1. Turn locking handle
or
2. Loosen both Torx screws
vice.
3. Hold the monitor or keyboard shelf and release lo‐
(1)
or (5).
cking handle
4. Adjust the height of the monitor or keyboard shelf.
Then, turn locking knob
ten it.
5. Tighten both Torx screws
vice.
---Separator---
3.8
System recovery
If the current software version causes problems or if
the DCI 700 is to be sold, reset the DCI 700 to factory
settings.
System recovery will delete all data and settings
from the DCI 700, e.g. licensing information, log
files, user settings, protocols, images.
 Internet connection required
 Keyboard required
 Customer number and password for login on DDM
---Separator---
Resetting the DCI 700 to factory settings
1. Backing up data and settings (see DCI 700 Help
Center).
2. Remove the cover from the computer unit.
3. Insert the recovery USB stick into an unused USB
(1)
(2)
port
or
of the computer unit.
2
4
5
(5)
clockwise to tighten it.
(3)
for the clamping de‐
(1)
(5)
or
clockwise to tigh‐
(1)
for the clamping de‐
Robert Bosch GmbH

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido