Bosch DCI 700 Manual Original página 18

Common-rail injector test bench
Tabla de contenido

Publicidad

en | 18 | DCI 700
1
2
 32:
Test oil tank
7. Attach the front left cover.
8. Check the fill level in the test oil tank after an injec‐
tor test. If necessary, top up the test oil.
---Separator---
4.2.3
Changing the test oil filter
---Separator---
4.2.3.1 Removing the test oil filter
1. End all computer applications.
2. Shut down the Windows operating system.
3. Switch off the DCI 700 at the main switch (2).
4. Remove the front left cover (1).
1
 33:
Preparing to change the test oil
1 689 989 473 | 2020-11-24
3
4
2
5. Release the two wing screws
move the wing screws.
(2)
6. Use the two handles
tank out of the test bench.
1
2
 34:
Test oil tank
7. Place a collecting container
ter.
8. Loosen the test oil filter
with the aid of a strap wrench.
9. Unscrew the test oil filter
test oil in the collecting container
 35:
Removing the test oil filter
10. Dispose of the test oil and test oil filter (see
"Disposal").
---Separator---
(1)
and (4). Do not re‐
(3)
and
to pull the test oil
3
4
(2)
under the test oil fil‐
(1)
by turning it clockwise
(1)
. Collect the draining
(2)
.
1
2
 25
Robert Bosch GmbH

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido