Filling With Test Oil - Bosch DCI 700 Manual Original

Common-rail injector test bench
Tabla de contenido

Publicidad

(2)
3. Insert the drain hose
(1)
ling
until it snaps in place.
 The test oil drains from the heat exchanger into
the collecting container.
2
1
 29:
Connecting the drain hose
4. Once the heat exchanger is empty at, open the
quick-release coupling and remove the drain hose
from the heat exchanger.
5. Dispose of the used test oil. Comply with disposal
 25 "Substances hazardous to wa-
instructions (see
ter").
6. Attach the cover.
---Separator---

4.2.2.4 Filling with test oil

1. Check whether the drain cock of the test oil tank
is closed.
Fill the test oil tank only with fresh and clean test
oil to ISO 4113-CV-AW. For approved test oil, see
 26 "Test oil conforming to ISO
ling quantity = approx. 50 liters.
2. Fill the test oil into the test oil tank through a fine
filter (1) up to the "max." marking
Robert Bosch GmbH
into the quick-release coup‐
(2)
4113-CV-AW". Fil‐
(3)
.
1
2
 30:
Filling with test oil
3. Slide the test oil tank cap
4. Tighten the two wing screws
1
3
 31:
Closing the test oil tank cap
(2)
5. Use the handles
and
into the test bench.
6. Tighten the two wing screws
DCI 700 | 17 | en
2
1
3
(2)
onto the test oil tank.
(1)
and (3).
2
(3)
to push the test oil tank
(1)
and (4).
1 689 989 473 | 2020-11-24

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido