Bosch DCI 700 Manual Original página 44

Common-rail injector test bench
Tabla de contenido

Publicidad

en | 44 | DCI 700
4.2.3.2 Installing the test oil filter
1. Make sure that the sealing surface on the new test
oil filter is clean.
2. Lubricate the sealing ring and threads of the test oil
filter with test oil.
3. Fill the test oil filter with fresh test oil.
4. Attach the test oil filter to the filter connection by
turning it counterclockwise until its seal presses
against the sealing surface of the socket.
5. Tighten the test oil filter by an additional 3/4 turn
manually.
 36:
Tightening the test oil filter
(2)
6. Use the handles
and
into the test bench.
7. Tighten the two wing screws
1 689 989 473 | 2020-11-24
(3)
to push the test oil tank
(1)
and (4).
1
2
 37:
Test oil tank
8. Switch on DCI 700 at the main switch.
9. In the DCI software: select "Maintenance."
10. Select the "System test" tab.
11. Select "Test oil filter change," and use <Start> to
start the bleeding process.
12. Follow the instructions and perform system bleed‐
ing.
13. After checking the level in the test oil tank, attach
the front left cover.
---Separator---
4.2.4
Changing the test oil filter in the inlet filter
---Separator---
4.2.4.1 Removing the inlet filter
DANGER
Hot components can cause burns immediately
after the test.
 Allow DCI 700 to cool before starting on the
work steps.
 Wear protective gloves.
---Separator---
3
4
Robert Bosch GmbH

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido