iCAT
9.1 Cleaning the iCAT ABIROB
1
9
8
1
Threaded sleeve
2
Cover ring
3
O-ring 28x1.5
Fig. 15
Cleaning the iCAT ABIROB
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• The maintenance intervals given are approximate values and refer to
single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified
personnel (in Germany see TRBS 1203).
• Always wear your personal protective equipment when performing
maintenance and cleaning work.
• When replacing the liquid-cooled ABIROB
assemblies, make sure that any coolant residues are removed from the
®
iCAT ABIROB
W, iCAT ROBO WH.
®
A
2
3
7
4
2 set screws
®
5
iCAT ABIROB
6
Screw
®
A
9 Maintenance and cleaning
®
7
Washer
A
8
Fastening screw
9
Threaded sleeve
W, ROBO WH hose
4
5
6
EN - 27