iCAT
9.4 Cleaning the iCAT ROBO WH
1
7
1
iCAT ROBO WH
2
Bellows
3
2 compression sleeves
Fig. 18
Cleaning the iCAT ROBO WH
5 Reinstall the screw (4), washer (6) and screw (5).
6 Mount bellows (2) and retaining ring (1).
4
2 O-rings
5
Screw
1 Clean the iCAT ROBO A (1) with compressed air.
2 Push bellows (2) laterally away.
3 Remove screw (5), washer (6) and fastening screw (7) and clean them
together with compressed air.
4 Blow compressed air through the bores.
5 Mount fastening screw (7), washer (6) and screw (5) again.
6 Release bellows (2).
7 Unscrew compression sleeves (3) and blow compressed air through the
bores.
8 Grease the pressure sleeves (3) and O-rings (4) with sealing grease
(included in the scope of delivery).
9 Mount pressure sleeves (3) again.
9 Maintenance and cleaning
2
6
6
Washer
7
Fastening screw
3
4
5