Care and maintenance

General notes
ATTENTION
Risk of damage!
 Do not rinse out the dust filter.
 Maintenance work may only be carried
out by approved customer service out-
lets or experts in this field who are famil-
iar with the respective safety regula-
tions.
 Always disconnect the battery when
working on the electrics.
 Mobile appliances used for commercial
purposes are subject to safety inspec-
tions according to VDE 0701.
 Park the sweeper on an even surface.
 Turn ignition key to "0" and remove it.
 Lock parking brake.
 Close the gas inlet.
Cleaning
CAUTION
Risk of damage!
 Do not clean the appliance with a water
hose or high-pressure water jet (danger
of short circuits or other damage).
Cleaning the inside of the machine
DANGER
Risk of injury!
 Wear dust mask and protective gog-
gles.
 Clean machine with a cloth.
 Blow through machine with com-
pressed air.
External cleaning of the appliance
 Clean the machine with a damp cloth
which has been soaked in mild deter-
gent.
Note: Do not use aggressive cleaning
agents.

Maintenance intervals

Note: The elapsed-time counter shows the
timing of the maintenance intervals.
Maintenance by the customer
Note: If maintenance is carried out by the
customer, all service and maintenance
work must be carried out by qualified staff.
An ISAL specialist dealer can be consulted
at any time if needed.
Daily maintenance:
 Check engine oil level.
 Check the filling level in the coolant ex-
pansion tank.
 Check the sweeping roller and the side
brush for wear and wrapped belts.
 Check the centrifugal separator and the
air filter, clean if required.
 Check function of all operator control el-
ements.
 Check appliance for damages.
Weekly maintenance:
 Check gas lines, connections and joints
 Clean the water cooler.
 Clean the hydraulic oil cooler.
 Check hydraulic unit.
 Check the hydraulic oil level.
 Check brake fluid status.
 Check the pad for wear, replace if re-
quired.
 Check the container lid and lubricate it.
Maintenance following wear:
 Replace sealing strips.
 Readjust the side seals or replace
them.
 Replace roller brush.
 Replace side brush.
Note: For description, see section on Main-
tenance work.
Maintenance by Customer Service
Note: In order to preserve warranty claims,
all servicing and maintenance work during
the warranty period has to be performed by
an authorised ISAL Customer Service, in
accordance with the inspection check list.
Maintenance to be carried out after 50
operating hours:
 Have the first maintenance performed
by the customer service in accordance
with the inspection check list.
Maintenance after 250/500/1000/1500/
2000 operating hours:
 Have the maintenance performed by
the customer service in accordance
with the inspection check list.
Maintenance Works
Preparation:
 Park the sweeper on an even surface.
 Turn ignition key to "0" and remove it.
 Lock parking brake.
 Close the gas inlet.
General notes on safety
DANGER
Risk of injury!
 Always apply the safety rod when the
waste container is raised.
 Perform the safeguarding only from
outside the hazard zone.
1 Holder of safety rod
2 Safety rod
 Fold the safety rod for the high empty-
ing up and insert it into the holder (se-
cured).
Do not allow fluids such as mo-
tor oil, hydraulic oil, brake fluid,
diesel or coolant to enter the
soil. Please protect the environ-
ment and dispose of fluids in an
environmentally responsible
way.
Safety notes regarding the batteries
Please observe the following warning notes
when handling batteries:
9
-
EN
Observe the directions on the
battery, in the instructions for
use and in the vehicle operat-
ing instructions!
Wear an eye shield!
Keep away children from acid
and batteries!
Risk of explosion!
Fire, sparks, open light, and
smoking not allowed!
Danger of causticization!
First aid!
Warning note!
Disposal!
Do not throw the battery in the
dustbin!
DANGER
Risk of explosion!
 Only use batteries with terminal cover.
Restore terminal cover in the event of
loss.
DANGER
Risk of explosion!
 Do not place tools or similar items on
the battery. Risk of short-circuit and ex-
plosion.
DANGER
Risk of injury!
 Ensure that wounds never come into
contact with lead. Always clean your
hands after working on batteries.
DANGER
Risk of fire and explosion!
 Smoking and naked flames are strictly
prohibited.
 Rooms where batteries are charged
must have good ventilation because
highly explosive gas is emitted during
charging.
DANGER
Danger of causticization!
 Rinse thoroughly with lots of clear water
if acid gets into the eye or comes in con-
tact with the skin.
 Then consult a doctor immediately.
 Wash off the acid If it comes in contact
with the clothes.
27