However, it must be noted that the use of a flameless device does not eliminate the risk area. The
high pressure and hot gases are still released into the surroundings, and this must be taken into
consideration when positioning the FlexPAK 800/1000 DX. Please consult your local fire authority
when determining suitable positioning of the FlexPAK 800/1000 DX with flameless device.
Please refer to the installation and service or user manual for the flameless device supplied with the
FlexPAK 800/1000 DX to find other limitations and information regarding safe use and service.
The use of a flameless device will also reduce the venting efficiency of the FlexPAK 800/1000 DX.
This means that the FlexPAK 800/1000 DX will not be able to be used with explosive dust types
with a higher Kst (ST type). The limit of the Kst value (ST–type) is determined by the parameters
of the specific flameless device.
3.3.4

Isolation device

An isolation device, see figure 9, item 2, is to be installed to prevent a filter explosion from
propagating back into the plant through the connected duct. The duct, see figure 9, item 3, between
the unit and the isolation device is to be pressure-resistant to an overpressure of at least 0.5 bar
(7.2 PSI) and have a minimum length as specified in the manual of the isolation device. This is
normally 4 meters for ST2 and 2 meters for ST1.
3.4

Dimensions

For the dimensions of FlexPAK 800/1000 DX, see figures 2A, 2B, and 2C.
NOTE!
Figure 2D shows the dimensions of the inlet and one side of FlexPAK 800/1000 DX.
3.5

Technical data

Table 3-1: Technical data FlexPAK 800 DX
FlexPAK 800 DX
Effect
Mains voltage/frequency
Maximum flow
Flow at -20 kPa
Maximum vacuum
Filter area
Weight
Inlet/outlet diameter (flanged)
Sound level
Filtration efficiency*
Maximum ambient temperature
Relative humidity
Compressed air
Material recycling
Control Filter area
Control Filter material
* According to DIN EN/IEC 60335-2-69.
18.5 kW (25 hp)
18.5 kW (25 hp)
230 V±10%/50–60 Hz
400 V±10%/50–60 Hz
1,300 m
/h (765 cfm)
1,300 m
3
800 m
/h (470 cfm)
800 m
3
-35 kPa (-5.1 PSI)
-35 kPa (-5.1 PSI)
6 m
(64.5 sqft)
6 m
2
439 kg (968 lb)
439 kg (968 lb)
150/160 mm (7.87/6.29")
150/160 mm (7.87/6.29")
70 dB(A)
70 dB(A)
Dust class L
Dust class L
-10 – +40 °C (14–104 °F)
-10 – +40 °C (14–104 °F)
Max. 85%
Max. 85%
6–7 bar (87–102 PSI)
6–7 bar (87–102 PSI)
93.6% per weight
93.6% per weight
1x12 m² (1x129 sqft)
1x12 m² (1x129 sqft)
Polyester
Polyester
FlexPAK 800/1000 DX
21.5 kW (29 hp)
460 V±10%/50–60 Hz
/h (765 cfm)
1,300 m
3
/h (470 cfm)
800 m
3
3
-35 kPa (-5.1 PSI)
(64.5 sqft)
6 m
(64.5 sqft)
2
2
439 kg (968 lb)
150/160 mm (7.87/6.29")
70 dB(A)
Dust class L
-10 – +40 °C (14–104 °F)
Max. 85%
6–7 bar (87–102 PSI)
93.6% per weight
1x12 m² (1x129 sqft)
Polyester