Descargar Imprimir esta página

Frequency Conv Alarm; Ptc Detect Hi Motor Temp Unit Shut Down; Hi Vacuum - Nederman FlexPAK 800 Manual Del Usuario

Ocultar thumbs Ver también para FlexPAK 800:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 152
EN
FlexPAK 800/1000 DX

Hi Vacuum

Exhaust Air Temp High
Auto Cleaning Cycle To Intermittent Filter Heavy Clogged Check Filter
Bag Replacement Switch Time Out
Control Filter Clogged
Error! TVFD Gate
TVFD Error! Upper Slide Not Closed
TVFD Error! Upper Slide Not Open
TVFD Error! Lower Slide Not Closed
TVFD Error! Lower Slide Not Open
TVFD Error! Slides In Open Position
6.4.1

Frequency Conv Alarm

The frequency converter has detected a problem and has put the unit into Off mode. The following
list shows the most common problems:
Connection problem to main power supply.
Motor cable problem.
Power supply fault.
There is a problem with the frequency converter.
Frequency
Conv Alarm
Reset OK==>
6.4.2

PTC Detect Hi Motor Temp Unit Shut Down

The frequency converter has detected that the PTC sensors in the motor have reached the
maximum temperature for the unit (140°C), so the unit has been put into Off mode.
PTC Detect Hi Motor Temp
Unit Shut Down
Reset OK==>
6.4.3
Hi Vacuum
The maximum vacuum level has been activated, and the delay time for the vacuum alarm has
elapsed. Press 'OK' to reset the alarm.
Hi Vacuum
Level -36kPa
Reset OK==>
36
All manuals and user guides at all-guides.com
ESC
OK
ESC
OK
.
ESC
OK

Publicidad

loading

Este manual también es adecuado para:

Flexpak 1000