8
Pneumatic filter cleaning valve
8.1
Filter cleaning button
The filter cleaning button will only work when the system is in Standby mode or Running mode.
8.2
Filter cleaning in Standby mode
Perform a filter cleaning in Standby mode as follows:
1.
From Off mode, put the unit into Standby mode by pressing the Standby/Running button.
2.
Start filter cleaning by pressing the filter cleaning button.
The unit goes into Running mode, the motor starts and the FCV closes and vacuum is established
in the system. The unit will now open and close the FCV once and then leave the FCV in its open
position. After the cleaning cycle, the unit goes into Idling mode. The unit waits for a pilot signal
for 10 minutes. If the pilot signal is not received during this time, the unit will stop its motor and
go into Standby mode.