6.1.1

Nederman FlexPAK Off (Off mode)

The unit is in Off mode, which is also the unit's start menu. The unit can also go into Off mode if
something is wrong, such as if an alarm is activated. The pump motor is off, there is no vacuum,
the FCV is closed, and the unit cannot be activated by a pilot signal.
Nederman
FlexPAK Off
TimeToService
2000Hour
6.1.2

FlexPAK Standby (Standby mode)

The unit is in Standby mode. The pump motor is off, there is no vacuum, the FCV is
closed, and the unit is waiting for a pilot signal to go into Running mode.
FlexPAK
Standby
TimeToService
2000Hour
6.1.3

Running (Running mode)

The unit in Running mode. The pump motor is on and the unit generates a vacuum. The FCV is
closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
Running
kPa -20
DIRTm 10:00s
OTTmr 00:00s
6.1.4

FlexPAK Idling (Idling mode)

The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open. The
unit goes into Idling mode when there has been no pilot signal for the time set in DIR_Time, see
Section '7.2.4 DIR_Time'.
FlexPAK
Idling
TimeToStandby
12:00m
6.1.5

Filter Cleaning

The unit is cleaning its main filter.
Filter
Cleaning
Clean 00:00
Wait 00:00
6.2

Status messages: Accessories, customer connections

Support for unit accessories is already built into the PLC. Depending on what accessories are in
use, the following messages may be seen in the PLC display.
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours.
See Section '7.2.3 H-Meter 1'.
ESC
OK
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours.
See Section '7.2.3 H-Meter 1'.
ESC
OK
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds. See also Section '7.2.4 DIR_Time'.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
ESC
OK
TimeToStandby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes.
See Section '7.2.5 SSR_Time'.
ESC
OK
Clean: The elapsed time since filter cleaning was activated.
Wait: If TVFD is being used, Filter Cleaning (FC), and bin emptying can
not start until this time has elapsed.
ESC
OK
FlexPAK 800/1000 DX
EN
33