Mod. "A" & "B" Fault Diagnosis And Warnings - Fagor evo CONCEPT Instrucciones De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para evo CONCEPT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
If the fault cannot be found, call the technical support service.
The manufacturer reserves the right to modify the technical characteristics of the
machine without prior warning.
7.1 MOD. "A" & "B" Fault diagnosis and warnings
In models with WASH TEMP and RINSE TEMP (Fig. 7 & 8) thermometers, the error code will be displayed.
Errors that do not disable the machine will appear every 3 minutes for 15 seconds until the machine is
turned off or the error is corrected.
In models without thermometers, errors are indicated by a LED error code via the ON LIGHT (Fig. 7), which
flashes as many times as the error number, pauses and then repeats the cycle. For example, in Error 3: 3
continuous flashes and a longer intermediate pause.
ERROR
1
E1 / BP
2
E2 / TP
3
E3 / BO
4
E4 / TO
5
E5 / BH
6
E6 / TH
7
E7 / DR
8
E8 / BF
9
10
10 / RS
80
CODE
BOILER
/
TEMPERATURE
PROBE ERROR
(Boiler Probe)
TANK
/
TEMPERATURE
PROBE ERROR
(Tank Probe)
/
BOILER
OVERHEATING
(Boiler Overheating)
/
TANK
OVERHEATING
(Tank Overheating)
/
BOILER HEATING
ERROR
(Boiler Heating)
/
TANK HEATING
ERROR
(Tank Heating)
/
TANK DRAINAGE
ERROR
(Drain)
/
BOILER FILLING
ERROR
(Boiler Filling)
/
TANK FILL ERROR
(Tank Filling)
E9 / TF
/
RINSE ERROR
(Rinse)
DESCRIPTION
Boiler temperature probe out of range or not
detected. (-5ºC -- 200ºC)
Machine disabled until turning off the device or
correcting the error.
Tank temperature probe out of range or not
detected. (-5ºC -- 200ºC)
Machine disabled until turning off the device or
correcting the error.
Boiler overheating (BC > 99ºC).
Machine disabled until turning off the device or
correcting the error.
Tank overheating (BT > 92ºC).
Machine disabled until turning off the device or
correcting the error.
Boiler heating faulty.
Message on display until the device is turned off.
Functional machine.
Tank heating faulty.
Message on display until the device is turned off.
Functional machine.
Tank drainage faulty.
Machine disabled until turning off the device or
correcting the error.
Only MOD "B" appliances: The boiler doesn´t fill
with water in 8 min.
Machine disabled until turning off the device or
correcting the error.
MOD "A": Tank doesn´t reach correct water level
in 15 min.
MOD "B": Water level in the boiler doesn´t drop
during the fill rinse.
Machine disabled until turning off the device or
correcting the error.
Only MOD "B" appliances: Water level in the
boiler doesn´t drop during rinse.
Machine disabled until turning off the device or
correcting the error.

Publicidad

Tabla de contenido
loading

Tabla de contenido