Mod. "C": Fault Diagnosis And Warnings On Display - Fagor evo CONCEPT Instrucciones De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para evo CONCEPT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DOOR/HOOD OPEN WARNING:
The door/hood open warning occurs when:
With the door/hood open an attempt is made to start a cycle that requires the door/hood to be
closed or the door/hood is opened during a cycle.
The door/hood is open while the appliance is filling. As long as the door/hood is not closed, the
warning will appear every minute.
DOOR/HOOD OPEN WARNING

7.2 MOD. "C": Fault diagnosis and warnings on display

The errors are shown on the DISPLAY (Fig. 9) with a flashing error warning and a buzzer alarm. The buzzer
alarm has a cycle of 30 s active and 150 s off until it is switched off after 15 minutes. The warning message
continues to be displayed until the error is resolved or the machine is switched off.
ERROR DISPLAY
E1-TC-BOILER TEMP.
E2-TT-TANK TEMP.
E3-TEMP. TANK
E4-BOILER TEMP.
E5-BOILER
DOES NOT HEAT
E6-TANK
DOES NOT HEAT
E7-NO WATER
E8-TANK DOES NOT
FILL
E9-DOES NOT DRAIN
E10-INCORRECT
RINSE
E11- TANK MAX.
LEVEL
E12- TANK MIN.
LEVEL TANK
WARNINGS:
A1-DOOR OPEN
A2-CHANGE WATER
A3-LOW WASH
TEMPERATURE
FLASHING
ON LIGHT.
Flashes for 4s.
DESCRIPTION
Faulty boiler temperature probe.
Faulty tank temperature probe.
Tank overheating
TT > 90 ºC
Boiler overheating
TC > 105 ºC
Boiler heating faulty.
TC does not increase 3 ºC in 5 minutes.
Tank heating failure.
60 min without reaching temperature.
The boiler does not fill.
After 10 minutes, the boiler does not fill.
The tank does not fill.
After 30 minutes, the tank does not fill.
Does not drain.
After 1 minute with the drainage pump running,
the level of the tank has not dropped 5 mm.
Rinse error.
The boiler level does not decrease during the
rinse cycle.
Max. tank level error.
The tank contains too much water.
Min. tank level error
The tank is running dry while in standby mode.
With the door/hood open an attempt is made to start a cycle that requires the
door/hood to be closed or the door/hood is opened during a cycle.
The door/hood is open while the appliance is filling.
The defined washing cycles have been carried out to renew the washing water
in the tank.
A washing cycle is carried out with a tank temperature lower than that required.
DOOR/HOOD OPEN WARNING
DISPLAY
Flashes for 4s.
The drainage pump runs
CONSEQUENCE
Machine disabled.
Machine disabled.
Machine disabled.
Machine disabled.
Alarm.
Alarm.
Machine disabled.
Machine disabled.
Machine disabled.
Alarm.
until the water level is
lowered.
Machine disabled.
81